User ManualCL-1208CL-12162005-04-26

Página 2

Setup is fast and easy; plugging cables into their appropriate ports is all thatis entailed. Because the CL-1208 / CL-1216 intercepts keyboard inputdi

Página 3 - Packing List

FeaturesM Integrated KVM console with 15"or 17" LCD monitor - in a SlideawayhousingM Slideaway housing is less than 1U - with top and bot

Página 4

Hardware RequirementsComputersThe following equipment must be installed on each computer:w A VGA, SVGA or Multisync card.Note: The integrated LCD moni

Página 5 - Table of Contents

Note: 1. The CL-1208 / CL-1216 does not support serial mice. You cannotuse Serial-to-PS/2 adapters with the cables. Attempts to do so willnot work.2.

Página 6

CL-1208 / CL-1216BL Front View23612910 & 1111313784 & 523612910 & 1111313784 & 52005-05-03CL-1208 / CL-1216 User Manual6

Página 7 - About This Manual

1 Handle Pull to slide the KVM module out; push to slide the modulein (see item 13 in this table).2 LCD Display After sliding the KVM module out, flip

Página 8 - Conventions

CL-1208 / CL-1216 Rear View12345123452005-04-26CL-1208 / CL-1216 User Manual8

Página 9

1Daisy ChainPortWhen Daisy Chaining Units, the cable plugs in here.2CPU PortSectionThe cables that link to the computers plug in here.Note: The shape

Página 10 - CL-1208 / CL-1216 User Manual

Notes:2005-04-26CL-1208 / CL-1216 User Manual10

Página 11 - Features

Chapter 2.InstallationBefore you BeginSingle Stage InstallationIn a Single Stage installation, there are no additional switches daisy chaineddown from

Página 12 - Hardware Requirements

Warning!This is a class A product. In a domestic environment thisproduct may cause radio interference in which case theuser may be required to take ad

Página 13 - Introduction

4. Power on the switch.5. After the switch is powered on, power on the computers.123422005-04-26CL-1208 / CL-1216 User Manual12

Página 14 - 2005-05-03

Daisy ChainingTo control even more computers, up to 31 Master View ACS-1208A /ACS-1216A units can be daisy chained down from the CL-1208 / CL-1216.Not

Página 15

5. Power up the installation according to the following procedure:a) Power on the First Station (CL-1208 or CL-1216).Wait a few seconds for the unit t

Página 16 - CL-1208 / CL-1216 Rear View

CL-1216ACS-1216AACS-1216A2005-04-26Installation15

Página 17

Notes:2005-04-26CL-1208 / CL-1216 User Manual16

Página 18

Chapter 3.Basic OperationOpening the ConsoleThe CL-1208 / CL-1216’s console is located under the top cover. To access theconsole, slide the console mo

Página 19 - Installation

Closing the ConsoleTo slide the console module back in, close the cover and do the following:1. Pull the safety catches on the unit’s side rails towar

Página 20 - 4. Power on the switch

LCD OSD ConfigurationThe LCD ButtonsThe LCD OSD allows you to set up and configure the LCD display. Four buttonsare used to perform the configuration,

Página 21 - Daisy Chaining

The Adjustment SettingsAn explanation of the LCD OSD adjustment settings is given in the tablebelow:Setting ExplanationBrightness Adjusts the backgrou

Página 22

Port SelectionThe CL-1208 / CL-1216 provides three port selection methods to access thecomputers on the installation: Manual; OSD (On Screen Display)

Página 23

Packing ListBasic PackageThe basic CL-1208 / CL-1216 package consists of the following equipment:M 1 CL-1208 / CL-1216 KVM Switch with Standard Rack M

Página 24

Hot PluggingThe CL-1208 / CL-1216 supports hot plugging - components can beremoved and added back into the installation by unplugging their cablesfrom

Página 25 - Basic Operation

Powering Off and RestartingIf it becomes necessary to Power Off one of the ACS- 1208A / ACS-1216Aunits, unplug the power adapter cable from the rear p

Página 26 - Closing the Console

Port ID NumberingEach CPU port on a Master View installation is assigned a unique Port ID. ThePort ID is made up of two parts: a Station Number, and a

Página 27 - LCD OSD Configuration

Chapter 4.OSD OperationOSD OverviewThe On Screen Display (OSD) is a menu driven method to handle computercontrol and switching operations. All procedu

Página 28 - The Adjustment Settings

When you invoke the OSD, a screen similar to the one below appears:Note: 1. The diagram depicts the Administrator’s Main Screen. The UserMain Screen d

Página 29 - Port Selection

OSD Navigationw To dismiss the menu, and deactivate the OSD, Click the X at the upperright corner of the OSD Window; or press [Esc].w To Logout, Click

Página 30 - Hot Plugging

OSD FunctionsOSD functions are used to configure and control the OSD. For example, youcan: rapidly switch to any port; scan selected ports only; limit

Página 31 - Powering Off and Restarting

F2 LIST:This function lets you broaden or narrow the scope of which ports the OSDdisplays (lists) on the Main Screen. Many of the OSD functions only o

Página 32 - Port ID Numbering

F3 SET:This function allows the Administrator and each User to set up their own,individual, working environment. A separate profile for each is stored

Página 33 - OSD Operation

(F3 SET: continued)Setting FunctionPORT IDDISPLAYMODESelects how the Port ID is displayed: the Port Number alone(PORT NUMBER); the Port Name alone (PO

Página 34

Notes:2005-04-26CL-1208 / CL-1216 User Manualiv

Página 35 - OSD Main Screen Headings

F4 ADM:F4 is an Administrator only function. It allows the Administrator toconfigure and control the overall operation of the OSD. To change a setting

Página 36 - OSD Functions

(F4 ADM: continued)Setting FunctionEDIT PORTNAMESTo help remember which computer is attached to a particular port,every port can be given a name. This

Página 37 - F2 LIST:

(F4 ADM: continued)Setting FunctionSET QUICKVIEW PORTSThis function lets the Administrator select which Ports to includeas Quick View ports.w To selec

Página 38

(F4 ADM: continued)Setting FunctionRESETSTATION IDSIf you change the position of one of the Stations in the daisychain, the OSD settings will no longe

Página 39 - (F3 SET: continued)

F5 SKP:This function enables you to easily skip backward or forward - switching theKVM focus from the currently active computer port to the previous o

Página 40

F6 BRC:F6 is an Administrator only function. When this function is in effect,commands sent from the console are broadcast to all available computers o

Página 41 - (F4 ADM: continued)

F7 SCAN:This function automatically switches among the available computers atregular intervals so that you can monitor their activity without having t

Página 42

F8 LOUT:Clicking the F8 field or, or pressing [F8] logs you out of the OSD, andblanks the Console screen. This is different from simply deactivating t

Página 43

Notes:2005-04-26CL-1208 / CL-1216 User Manual40

Página 44

Chapter 5. Hotkey Operation Hotkey Port AccessHotkey Port Access allows you to provide the KVM focus to any computeron your installation directly from

Página 45

Table of Contents1. IntroductionOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Features . .

Página 46

When Hotkey Mode is active:M The Caps Lock, and Scroll Lock LEDs flash in succession to indicate so.They stop flashing and revert to normal status whe

Página 47 - F8 LOUT:

Auto ScanningAuto Scan automatically switches among all the active CPU Ports that areaccessible to the currently logged on User at regular intervals,

Página 48

Invoking Auto Scan:To start Auto Scanning, key in the following Hotkey combination:1. Invoke HKM (see p. 41).2. Press [A]. When you press A, you autom

Página 49 - Hotkey Operation

Skip ModeThis feature allows you to switch between computers in order to monitorthem manually. You can dwell on a particular port for as long or as li

Página 50 - Selecting the Active Port

Hotkey Beeper ControlThe Beeper can be Hotkey toggled On and Off (see Activate Beeper, p. 33).To toggle the Beeper, key in the following Hotkey combin

Página 51 - Auto Scanning

Hotkey Summary Table[Num Lock] + [-] [Port ID] [Enter] Switches access to the computer thatcorresponds to that Port ID.[T] [n] [Enter] Sets the Auto

Página 52

Notes:2005-04-26CL-1208 / CL-1216 User Manual48

Página 53 - Skip Mode

Chapter 6.The Firmware Upgrade UtilityThe Windows-based Firmware Upgrade Utility (FWUpgrade.exe) provides asmooth, automated process for upgrading the

Página 54 - Hotkey Beeper Control

PreparationTo prepare for the firmware upgrade, do the following:1. From a computer that is not part of your KVM installation go to ourInternet suppor

Página 55 - Hotkey Summary Table

Starting the UpgradeTo upgrade your firmware:1. Run the downloaded Firmware Upgrade Package file - either by doubleclicking the file icon, or by openi

Página 56

F7 SCAN: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38F8 LOUT: . . . . . . . . . . . . . . .

Página 57 - The Firmware Upgrade Utility

3. Click Next to continue. The Firmware Upgrade Utility main screenappears. The devices capable of being upgraded are listed in the DeviceList panel:4

Página 58 - Preparation

5. After you have made your device selection(s), Click Next to perform theupgrade.If you enabled Check Firmware Version, the Utility compares thedevic

Página 59 - Starting the Upgrade

Upgrade SucceededAfter the upgrade has completed, a screen appears to inform you that theprocedure was successful:Click Finish to close the Firmware U

Página 60 - Description panel

Firmware Upgrade RecoveryThere are basically three conditions that call for firmware upgrade recovery:M When you invoke Firmware Upgrade Mode (see p.

Página 61

Notes:2005-04-26CL-1208 / CL-1216 User Manual56

Página 62 - Upgrade Failed

AppendixConnection TablesThe following tables indicate the relationship between the number of MasterView units and the number of computers that they c

Página 63 - Firmware Upgrade Recovery

OSD Factory Default SettingsThe factory default settings are as follows:Setting DefaultOSD Hotkey [Scroll Lock] [Scroll Lock]Port ID Display Position

Página 64

Clear Login InformationIf you are unable to perform an Administrator login (because the Usernameand Password information has become corrupted, or you

Página 65 - Appendix

Rack MountingStandard Rack MountingA standard rack mounting kit is provided with your CL-1208 / CL-1216. Thekit enables the switch to be mounted in ra

Página 66 - OSD Factory Default Settings

Optional Rack MountingFor convenience and flexibility, three optional rack mounting kits areavailable: 1) a long bracket (68.0 - 110.0 cm) standard ra

Página 67 - Clear Login Information

About This ManualThis User Manual is provided to help you get the most from your CL-1208 /CL-1216 system. It covers all aspects of installation, confi

Página 68 - Rack Mounting

2. Attach the left and right easy-installation mounting rails to the inside ofthe rack. The flange that supports the switch will be to the inside.a) S

Página 69 - M3 x 8

3. Slide the switch onto the support flanges and secure it to the mountingrails at the front.4. Slide the rear attachment sliding bracket along the sl

Página 70

SpecificationsFunction CL-1208 CL-1216ComputerConnectionsDirect 8 16Max 256 (via Daisy Chain) 512 (via Daisy Chain)Port Selection Push button switches

Página 71

TroubleshootingProblem SolutionThere are ghost imageson the external monitor.The distance between the external console and theCL-1208 / CL-1216 is too